Koworase X
Koworase X is a specialized system for removing burn-in effects on Computed Radiography (CR) image plates. It restores image quality and sensitivity without damaging the plate and meets the requirements of the ASTM E2445 standard. The system uses a two-phase process that combines UV-C exposure and powerful LED light to eliminate deep image artifacts.
How does it work?
The deletion takes place in two steps:
First, the plate is exposed to intense UV-C illumination (254 nm) which saturates the phosphor layer.
Then, white, red and green LED lights are activated, removing any remaining burn-in and reducing the background level to a minimum.
The result is a completely clean plate with a maximum grayscale difference of 0.5%, which is better than the standard requirement of 1%. The sensitivity and life of the plate are not affected.
Important features
Active erase size up to 490 × 370 mm
Erasing time of 3–6 minutes, depending on disc wear
Operating voltage 90–260 V and power consumption of approximately 90 W
Robust steel construction with pull-out drawer for easy handling
Possibility of additional feeding table for long plates
Benefits
Fast and effective removal of image artifacts
Maintains image quality according to ASTM standards
Gentle process that does not reduce the sensitivity of the plate
Compatible with all common CR plate manufacturers
Ideal for industrial X-ray inspection and workshop use